Enter measurements in chronological order.
| Date (YYYY-MM) | Global RNFL (µm) | Reliability |
|---|
Uses global RNFL only — sector and GCC analysis not included. Segmentation errors and scan artefacts may produce apparent thinning. Floor effect limits sensitivity at advanced stages. Short series may show amplified slope variance.
Evidence-informed structural progression analysis based on serial OCT RNFL data. Does not replace clinical judgment or comprehensive evaluation of OCT findings.
This tool analyses longitudinal peripapillary RNFL thickness values using linear regression to estimate the rate of structural change over time. Classification is based on deterministic rule-based logic and is intended as a structured decision support aid, not as a standalone diagnostic conclusion.
OCT RNFL interpretation may be affected by segmentation errors, signal quality artefacts, device variability, anatomic variation (high myopia, tilted disc, peripapillary atrophy, ERM), floor effect, and the inherent limitations of serial trend analysis with short follow-up. RNFL slope estimation requires adequate serial data; results from small or short series should be interpreted with caution. Global RNFL does not capture sector-level or focal structural loss.
The clinician retains full responsibility for all diagnostic and therapeutic decisions. This tool is intended as a decision-support aid, consistent with current glaucoma guidelines, and is not a substitute for clinical evaluation. Not intended for patient self-use.
- Weinreb RN, Khaw PT. Primary open-angle glaucoma. Lancet. 2004;363(9422):1711–1720.
- Mwanza JC, Budenz DL. Optical coherence tomography platforms and parameters for glaucoma diagnosis and progression. Curr Opin Ophthalmol. 2018;29(2):101–110.
- Leung CK, Cheung CY, Weinreb RN, et al. Retinal nerve fiber layer imaging with spectral-domain optical coherence tomography: a variability and diagnostic performance study. Ophthalmology. 2009;116(7):1257–1263.
- Medeiros FA, Zangwill LM, Bowd C, et al. Evaluation of retinal nerve fiber layer, optic nerve head, and macular thickness measurements for glaucoma detection using optical coherence tomography. Am J Ophthalmol. 2005;139(1):44–55.
- European Glaucoma Society. Terminology and Guidelines for Glaucoma. 6th ed. 2025.
- Gedde SJ, Vinod K, Wright MM, et al. Primary open-angle glaucoma preferred practice pattern. Ophthalmology. 2021;128(1S):P71–P150.
-
v1.1Jul 2026
- Balanced wording for Low-quality terminal scans (M4-06): artefact and true structural loss are both acknowledged, without implying artefact is more likely
- Independently established pre-final fast structural trends are now preserved despite a Low-reliability final scan (M4-12)
- A Low-reliability final scan reduces confidence and requires repeat confirmation of the current rate
- Non-significant short-series slopes remain Suspicious trend (M4-11 p-value guard unchanged)
- Stale stored results are now cleared whenever a clinically relevant input changes
- Algorithm updated to v1.3.0
- Regression method, corrected p-value implementation, and numerical thresholds unchanged
-
v1.0Apr 2026
- First public release
- Rule-based OLS regression on serial peripapillary RNFL measurements
- Cascade classification: floor effect, artifact detection, V-shape artefact, slope-based
- Confidence level with reliability and modifier adjustments
- Clinical Risk output with structured interpretation text
- Clinical modifiers: high myopia, ERM maculopathy
- Sparkline chart with structural floor reference
- Mobile-optimised UI with gap warning and Excel-style navigation