Inherits the limitations of upstream M1–M4 outputs. Discordance between structural and functional domains is flagged but not algorithmically resolved. Assumes input coherence across modules (same patient, same eye, same monitoring window).
Rule-based integration of OFTY M1–M4 outputs into a structured multi-domain glaucoma assessment. Does not replace physician judgment or clinical evaluation.
This tool combines the structured outputs of OFTY-Gx-M1, M2, M3, and M4 into a single integrated assessment using deterministic rule-based logic. No machine learning, no probabilistic models, no treatment recommendations are generated.
The integrated interpretation surfaces structural–functional patterns, IOP target adherence, and confidence/risk levels in descriptive form only. Discordance between domains, signal-limited contexts (high myopia, ERM, RNFL floor effect), and incomplete data are explicitly flagged rather than masked.
The output is a structured decision-support aid consistent with current glaucoma guidelines (EGS 6th ed., AAO PPP 2021). It establishes computational integration of upstream module outputs and has not been clinically validated against expert adjudication or longitudinal outcomes.
The clinician retains full responsibility for all diagnostic and therapeutic decisions. This tool is intended as a decision-support aid and is not a substitute for clinical evaluation, specialist consultation, or comprehensive examination. Not intended for patient self-use.
- European Glaucoma Society. Terminology and Guidelines for Glaucoma. 6th ed. 2025.
- Gedde SJ, Vinod K, Wright MM, et al. Primary open-angle glaucoma preferred practice pattern. Ophthalmology. 2021;128(1S):P71–P150.
- Heijl A, Leske MC, Bengtsson B, et al. Reduction of intraocular pressure and glaucoma progression: results from the Early Manifest Glaucoma Trial. Arch Ophthalmol. 2002;120(10):1268–1279.
- Kass MA, Heuer DK, Higginbotham EJ, et al. The Ocular Hypertension Treatment Study. Arch Ophthalmol. 2002;120(6):701–713.
- Medeiros FA, Zangwill LM, Anderson DR, et al. Estimating the rate of retinal nerve fiber layer loss in healthy and glaucomatous eyes. Am J Ophthalmol. 2012;154(5):814–824.
- Hood DC, Kardon RH. A framework for comparing structural and functional measures of glaucomatous damage. Prog Retin Eye Res. 2007;26(6):688–710.
-
v1.2Jul 2026
- Strict structural/vocabulary validation of stored M1–M4 imports before use (validateM1Import…validateM4Import)
- Adapters no longer apply silent fallback defaults; a malformed or unsupported stored module is rejected and treated as absent rather than substituted with a default clinical value
- New contextual "Import unavailable" badge and non-blocking yellow banner shown on a domain card when its stored import is invalid
- Session bar counts only validated imports and notes any modules that could not be used
- Algorithm updated to v1.2.0
- Existing pattern, IOP, risk, classification, and clinical-caution logic unchanged
-
v1.1Jul 2026
- Prudent weighting of manual M3/M4 entries (limited data quality, low confidence); clinician-selected classification and clinical risk remain unchanged
- Selective propagation of clinically important upstream M3/M4 cautions into a new integrated Clinical cautions section
- Maximum three prioritised cautions shown beside the integrated result, ordered by clinical priority
- Complete caution provenance retained in structured output and technical details for audit
- Algorithm updated to v1.1.0
- Existing pattern, IOP, risk, and classification logic unchanged
-
v1.0Apr 2026
- First public release of the OFTY Glaucoma Suite Orchestrator
- Deterministic rule-based integration of M1–M4 outputs
- 8 pattern branches (P1–P8) covering all structural-functional state combinations
- 10+ risk rules (R1–R10) with explicit IOP target overlay
- localStorage import support from M1–M4 in same browser session
- Full manual fallback for each domain block
- Result card with classification, risk, confidence, interpretation, and logic trace
- Validated against 23 manual scenarios + 192 combinatorial stress test cases