Patient Parameters
5 – 60 mmHg
250 – 750 µm
IOP Estimate
--
mmHg
Model output
Measured GAT IOP
--
CCT
Model-derived offset
--
Impact
--
CAUTION
MODEL LIMITATION
Corneal biomechanics not assessed
Share feedback or report a case

Does not replace clinical judgment or tonometric assessment. Thin CCT is an independent risk factor for glaucoma development (OHTS).

Simplified linear pachymetric contextualization model: IOP estimate = measured GAT IOP − (CCT − 540) / 25, using 540 µm as the reference CCT and 1 mmHg per 25 µm as the linear factor.

This is a model output, not a direct pressure measurement or a validated individual-eye correction. Measured GAT IOP remains the reference value.

Individual corneal biomechanics—including hysteresis, rigidity, and other structural properties—are not accounted for by this model. Extreme CCT values and large model-derived offsets require additional caution.

The output is intended for structured interpretation and caution flagging only. It must not be used on its own to guide diagnosis or treatment. The clinician retains full responsibility for all diagnostic and therapeutic decisions. Not intended for patient self-use.

  • Ehlers N, Bramsen T, Sperling S. Applanation tonometry and central corneal thickness. Acta Ophthalmol. 1975;53(1):34–43.
  • Kohlhaas M, Boehm AG, Spoerl E, et al. Effect of central corneal thickness, corneal curvature, and axial length on applanation tonometry. Arch Ophthalmol. 2006;124(4):471–476.
  • Doughty MJ, Zaman ML. Human corneal thickness and its impact on intraocular pressure measures: a review and meta-analysis approach. Surv Ophthalmol. 2000;44(5):367–408.
  • Park SJK, Ang GS, Nicholas S, Wells AP. The effect of thin, thick, and normal corneas on Goldmann intraocular pressure measurements and correction formulae in individual eyes. Ophthalmology. 2012;119(3):443–449.
  • Gordon MO, Beiser JA, Brandt JD, et al. The Ocular Hypertension Treatment Study: baseline factors that predict the onset of primary open-angle glaucoma. Arch Ophthalmol. 2002;120(6):714–720.
  • UI v1.1.0Jul 2026
    • Result terminology and hierarchy refined
    • Impact, model limitation and case-specific cautions surfaced
    • Disclaimer and scientific sources updated
    • Result lifecycle, validation and accessibility improved
    • Algorithm unchanged: v1.0.0
  • v1.0Mar 2026
    • Initial public release
    • Result card: inline unit display, structured detail rows
    • Disclaimer and Sources finalized (Ehlers 1975, EGS 6th ed.)
    • Light mode enforced; Safari/iOS compatibility improved